Layer thickness is one of the most quoted and least examined specifications in jewelry manufacturing. This guide covers the units, the measurement methods, and the one question that exposes most confused reports.
The units, and how they convert
| Unit | Symbol | Conversion |
|---|---|---|
| Micrometre | µm | 1 µm = 0.001 mm |
| Microinch | µin | 1 µm ≈ 39.37 µin |
| Mil | mil | 1 mil = 25.4 µm (not the same as a millimetre) |
The total film trap
This is where most confusion starts. On a PVD coating, the total film may consist of a bond layer, a colour layer and a top layer. On decorative PVD for stainless steel jewelry, that total typically runs 0.03 - 0.1 µm - comfortably under one micron - so a report quoting a total film of one micron is describing a different class of coating altogether. Even within the correct range, a total figure tells you nothing about how much material actually sits in the colour layer, which is the layer that determines the appearance and the wear behaviour.
The same applies to multi-layer electroplating, where a nickel barrier layer and a top layer are deposited separately. A single headline number can be technically true and commercially meaningless.
The questions that resolve it
- Which layer does this number describe - total film, or the colour layer specifically?
- Was it measured by XRF or by cross-section microscopy?
- How many measurement points per part, and at which locations on the part?
- Was the measurement taken on a new part or a worn part?
- What is the tolerance, and what is the acceptance range for the order?
How XRF measurement works
X-ray fluorescence is a non-destructive method. X-rays excite the atoms in the coating, and the emitted spectrum identifies which elements are present and estimates how thick the layer is. It is fast, it works on finished parts, and it can be repeated on the same piece.
Its limitations
- It measures a small spot - a single reading is not representative of a whole curved or textured part
- Curvature and surface roughness both affect the reading
- It struggles to separate layers with similar elemental composition
- Thin layers sit near the method's detection floor, where relative error grows
Cross-section microscopy is destructive but more definitive: the part is mounted, cut, polished and examined under magnification, and each layer is measured directly. Where the stakes are high, this is the method that settles a disagreement.
Reading a report properly
- Check the unit
Micrometres, microinches or mils. Confirm which, in writing.
- Check which layer
Total film and colour layer are different specifications.
- Check the method
XRF and cross-section are not interchangeable, and they do not always agree.
- Check the sample
Worn-condition testing and new-part testing answer different questions.
- Check the tolerance
A number without an acceptance range is not a specification you can inspect against.
Need this specified for your order?
Send us your drawing, sample or technical requirement. We will confirm feasibility, tolerances and price in writing before production.
Request a Quote